WaterTreatmentSourceWater treatment, filtration, dosing, wastewater, membranes, and environmental equipment for global industrial buyers.
Brackish Water RO Membrane - SHANGHAI CM
Water Pumps

Brackish Water RO Membrane - SHANGHAI CM | RFQ Sourcing Details

Water Pumps · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryWater Pumps
Unitset
ModelEffective Membrane Area ft²(m²) Average Yield GPD(m³/d) Salt Rejection (%) Recovery Rate (%)
CategoryWater Pumps
AvailabilityInquiry required
Updated2026-05-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Water Pumps. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Industrial Grade BWRO Brackish Water RO Membrane High-Rejection Industrial BWRO Membrane for 2,000-10,000 ppm TDS Applications Stable Performance for Groundwater & Industrial Feed Water Get a Solution Now 99.7% Salt Rejection Stable Performance for Critical Applications When treating brackish water, unstable membrane performance can lead to: Increased energy consumption Frequent CIP cleaning Unstable permeate conductivity Reduced recovery rate Unexpected replacement costs Our BWRO Solution Delivers: Stable ≥99% salt rejection Optimized operating pressure Reduced fouling tendency Extended membrane lifespan Reliable compatibility with standard 4040 & 8040 vessels Designed for industrial RO systems operating continuously in municipal, power plant, and manufacturing environments.

Core Product Models Industry-standard configurations for scalable RO systems 4040 Brackish Water RO Membrane 4" × 40" standard element Ideal for small & mid-scale systems Stable performance for 2-8 m³/h RO units Suitable for pharmaceutical, food processing, and small industrial plants Request Quote → 8040 Brackish Water RO Membrane 8" × 40" industrial standard Designed for large-scale RO skids High active membrane area Optimized for municipal & industrial applications Request Quote → Brackish Water RO Membrane Specifications Technical parameters for industrial reverse osmosis membrane models Model Effective Membrane Area ft²(m²) Average Yield GPD(m³/d) Salt Rejection (%) Recovery Rate (%) BW- BW- BW- BW- BW- BW- Note: All specifications are measured under standard test conditions (25°C, 2000 ppm Na.

Cl, 15% recovery for 4040/8040/8440 models). Actual performance may vary based on feed water quality and operating conditions. Why Engineering Companies Choose Our BWRO Membranes 1. Balanced Flux & Rejection Design High flux alone increases fouling risk. High rejection alone increases pump load.

Our membranes are calibrated to maintain: Stable permeate conductivity Controlled permeate flow Lower differential pressure growth This balance significantly reduces cleaning frequency and operating cost. 2.

Lower Operating Pressure = Lower Energy Cost Compared to conventional medium-pressure membranes: Reduced pump power consumption Lower mechanical stress Improved long-term stability Over a 3-5 year operating cycle, energy savings substantially reduce total project cost. 3.

Enhanced Anti-Fouling Surface Hydrophilic surface modification improves: Organic fouling resistance Biofouling control Cleanability during CIP When combined with proper pretreatment (SDI ≤ 5), membranes maintain stable output under industrial conditions.

Application Scenarios Our Brackish Water RO Membranes are widely applied in: Groundwater Desalination Municipal and industrial groundwater treatment Municipal Water Treatment Large-scale water treatment plants Boiler Feed Water Preparation for power plants and industrial boilers Textile Industry Process water systems and wastewater treatment Electronics Manufacturing High-purity water for semiconductor production Industrial Wastewater Reuse After proper pretreatment for water recycling If your feed water TDS is below 10,000 ppm , BWRO membranes are typically the most cost-efficient solution.

Replacement & OEM Capability Our membranes are fully compatible with: Standard 4040 & 8040 pressure vessels International industrial RO system configurations Available Services: OEM private label manufacturing Bulk project supply Technical data support Stable long-term export supply Engineering consultation For distributors and project contractors, we ensure consistent batch quality and reliable lead times.

Technical Operating Limits To ensure optimal lifespan Maximum Operating Pressure 600 psi Max Temperature 45°C pH Range (continuous) 2-11 SDI ≤ 5 Free Chlorine < 0.1 ppm Correct pretreatment design is essential for long-term stability.

How to Select the Right BWRO Membrane We Require: 1 Feed water analysis report 2 Required permeate capacity (m³/h) 3 Target recovery rate 4 Application type Our Engineering Team Will: Evaluate scaling risk Estimate expected permeate conductivity Recommend optimal membrane configuration Provide project quotation Response time: within 24 hours.

Cost Optimization for EPC & Integrators For engineering companies and system integrators Competitive Pricing Wholesale pricing for bulk orders Stable Capacity Reliable production capacity Flexible Cooperation Project cooperation models Custom Branding Custom packaging & branding We support municipal engineering firms, industrial EPC contractors, and water treatment integrators globally.

Frequently Asked Questions Technical guidance for brackish water RO membrane selection and operation Still have technical questions about membrane selection or replacement? Send us your water analysis report -- our engineers will assist you directly. What TDS range is suitable for brackish water RO membranes?

Brackish water RO membranes are typically designed for feed water with TDS between 2,000-10,000 ppm . If salinity exceeds this range, a seawater RO membrane is usually recommended due to higher operating pressure requirements. What is the difference between BWRO and SWRO membranes?

The main differences are: Operating pressure Salt rejection structure Structural strength Energy consumption BWRO membranes operate at lower pressure and are optimized for medium salinity water, while SWRO membranes are designed for high-salinity seawater applications. What is the typical salt rejection rate?

Under standard test conditions (2,000 ppm Na. Cl, 25°C, 15% recovery): 4040 BWRO membrane: ≥ 99% 8040 BWRO membrane: ≥ 99.5% Actual rejection depends on feed water composition and system design. How long does a brackish water RO membrane last?

With proper pretreatment (SDI ≤ 5, turbidity < 1 NTU), typical service life is 3-5 years under industrial operation. Factors affecting lifespan include: Scaling tendency Organic fouling Cleaning frequency Operating pressure Can your membranes replace international brand elements directly? Yes.

Our 4040 and 8040 brackish water RO membranes are dimensionally compatible with standard industrial pressure vessels and can be used as direct replacements in most existing systems without structural modification. We recommend verifying operating pressure and flow design before replacement.

What pretreatment is required before BWRO membranes?

To protect membrane performance, the feed water should meet: SDI ≤ 5 Turbidity < 1 NTU No free chlorine (≤ 0.1 ppm) Proper hardness control to prevent scaling Typical pretreatment includes: Multimedia filtration Activated carbon filtration Softening or antiscalant dosing Cartridge filtration (5 micron) How often should membranes be cleaned (CIP)?

Cleaning is recommended when: Permeate flow declines by 10-15% Salt rejection drops by 10% Pressure differential increases by 15% Actual cleaning frequency depends on feed water quality and system recovery rate. What is the recommended recovery rate for brackish water systems?

Typical system recovery: 60-75% for groundwater applications Lower recovery may be required for high scaling risk water Recovery design should be based on full water analysis and scaling calculation. Do you provide membrane selection support for projects? Yes.

If you provide: Feed water analysis Target permeate capacity Application type Required recovery rate Our engineering team will recommend suitable membrane models and provide technical support within 24 hours. Do you support OEM or private labeling? Yes.

We provide: OEM branding Custom packaging Bulk project supply Stable export logistics Long-term cooperation for distributors and EPC contractors All membranes undergo individual wet testing before shipment. Request Technical Datasheet or Project Quotation If you are curren

Brackish | Applications and Buyer Notes

Brackish is organized as a sourcing-ready Water Pumps reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions be

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Water PumpsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Model
Effective Membrane Area ft²(m²) Average Yield GPD(m³/d) Salt Rejection (%) RecovBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryWater Pumps
Unitset
ModelEffective Membrane Area ft²(m²) Average Yield GPD(m³/d) Salt Rejection (%) Recovery Rate (%)

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

WaterTreatmentSource related sourcing paths

WaterTreatmentSource procurement phrases

WaterTreatmentSource related product samples

Supplier profile

WaterTreatmentSource Imported Supplier Pool
主营:Water Pumps

View full profile >