WaterTreatmentSourceWater treatment, filtration, dosing, wastewater, membranes, and environmental equipment for global industrial buyers.
City Water Treatment UF Hollow-Fiber Membrane Filtration System
Filtration And Membranes

City Water Treatment UF Hollow-Fiber Membrane Fil | RFQ Sourcing Details

Filtration And Membranes · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryFiltration and Membranes
Unitset
Net weight18 kg;37 kg
Wet weight26 kg;58 kg
CustomizationAvailable
Membrane typeInternal-pressure hollow fiber
Models listedLH3-0650-V;LH3-1060-V
Module dimensionsΦ187 × 1,398 mm;Φ277 × 1,715 mm
CategoryFiltration And Membranes
AvailabilityInquiry required
Source date2026-07-22

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Filtration And Membranes. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

This ultrafiltration system is intended for city and municipal water-treatment projects. The supplied information describes hollow-fiber UF membrane modules operating in an outside-in filtration configuration, with a stated molecular weight cutoff of 50,000 Daltons.

The module specifications list epoxy resin as the end-potting material and hollow-fiber inside/outside diameters of 1.0/1.6 mm. Two module configurations are listed. The LH3-0650-V has a standard membrane area of 11 m², a designed water-flux range of 158–422 gallons per hour, and a net weight of 18 kg.

The LH3-1060-V has a 40 m² membrane area, a designed range of 634–1,690 gallons per hour, and a net weight of 37 kg. The common designed flux is stated as 16–42 gallons per square metre per hour. Listed module dimensions are Φ187 × 1,398 mm and Φ277 × 1,715 mm, respectively.

The source information reports filtered-water turbidity below 0.1 NTU. It also lists no detection of general coliforms in each 100 ml sample, fecal coliforms in each 100 ml sample, and bacteria in each 1 ml sample.

Buyers should request the applicable test method, feed-water conditions, operating pressure, sampling protocol, and verification documents before treating these figures as project acceptance criteria.

Listed application areas include municipal, surface, well, and drinking-water treatment;reverse-osmosis pretreatment and post-treatment;wastewater polishing for reuse;condensate recovery;and process-water treatment for food and beverage production.

Other stated uses include turbidity removal for wine, pharmaceutical-water pyrogen removal, food and milk concentration processes, and medical filtration. Suitability for any specific duty must be confirmed against the actual feed-water analysis and regulatory requirements. Customization is stated as available.

Before procurement, confirm whether the quotation covers a complete treatment system, a skid, or membrane modules only.

Buyers should also establish required design flow, recovery, pretreatment, cleaning method, instrumentation, controls, module quantity, connection details, utilities, installation scope, commissioning, consumables, documentation, packing, delivery schedule, and after-sales terms.

Material descriptions in the supplied information are not fully consistent, so the membrane material and all wetted construction materials should be confirmed in the final technical schedule.

City | Applications and Buyer Notes

City is organized as a sourcing-ready Filtration And Membranes reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time que

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Filtration and MembranesBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Net weight
18 kg;37 kgBased on visible page data; confirm exact value in the RFQ.
Wet weight
26 kg;58 kgBased on visible page data; confirm exact value in the RFQ.
Customization
AvailableBased on visible page data; confirm exact value in the RFQ.
Membrane type
Internal-pressure hollow fiberBased on visible page data; confirm exact value in the RFQ.
Models listed
LH3-0650-V;LH3-1060-VBased on visible page data; confirm exact value in the RFQ.
Module dimensions
Φ187 × 1,398 mm;Φ277 × 1,715 mmBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryFiltration and Membranes
Unitset
Net weight18 kg;37 kg
Wet weight26 kg;58 kg
CustomizationAvailable
Membrane typeInternal-pressure hollow fiber
Models listedLH3-0650-V;LH3-1060-V
Module dimensionsΦ187 × 1,398 mm;Φ277 × 1,715 mm
Initial water flux1,056 gal/h;3,960 gal/h
Designed water flux158–422 gal/h;634–1,690 gal/h
Membrane technologyUltrafiltration (UF), hollow fiber
End-potting materialEpoxy resin
Hollow-fiber quantity3,940;11,000
Standard membrane area11 m²;40 m²
Molecular weight cutoff50,000 Daltons
Filtration configurationOutside-in
Designed membrane-area flux16–42 gal/m²/h
Hollow-fiber inside/outside diameter1.0/1.6 mm

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

WaterTreatmentSource related sourcing paths

WaterTreatmentSource procurement phrases

WaterTreatmentSource related product samples

Supplier profile

WaterTreatmentSource Imported Supplier Pool
主营:Filtration and Membranes

View full profile >