WaterTreatmentSourceWater treatment, filtration, dosing, wastewater, membranes, and environmental equipment for global industrial buyers.
DNF1/DNF2 4040 and 8040 Spiral-Wound Nanofiltration Membrane Elements
Filtration And Membranes

DNF1/DNF2 4040 and 8040 Spiral-Wound Nanofiltrati | RFQ Sourcing Details

Filtration And Membranes · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryFiltration and Membranes
Unitset
ModelsDNF1-4040, DNF1-8040, DNF2-4040, DNF2-8040
MaterialAromatic polyamide
StructureSpiral-wound
Membrane typeNanofiltration (NF)
Standard test pH6.5-7
Maximum feed flow17 m³/h for 8040;3.6 m³/h for 4040
CategoryFiltration And Membranes
AvailabilityInquiry required
Source date2026-07-22

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Filtration And Membranes. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

The DNF1/DNF2 series consists of spiral-wound aromatic polyamide nanofiltration membrane elements for material separation and concentration. Available models are DNF1-4040, DNF1-8040, DNF2-4040, and DNF2-8040. The 8040 elements have a stated active membrane area of 37 m², while the 4040 elements have 7.6 m².

All listed models use a 34 mil feed spacer. DNF1 is configured for high total organic carbon removal with medium inorganic-salt rejection. Under the stated standard test conditions, its magnesium sulfate rejection is at least 98% and its sodium chloride rejection is 30% ±10%.

Published permeate flow is 40 m³/day for DNF1-8040 and 8 m³/day for DNF1-4040. DNF2 is intended for higher rejection of multivalent ions while maintaining lower rejection of monovalent ions. Under the stated test conditions, magnesium sulfate rejection is at least 98% and sodium chloride rejection is 60% ±10%.

Published permeate flow is 38 m³/day for DNF2-8040 and 7.6 m³/day for DNF2-4040. DNF1 performance testing uses 2,000 mg/L MgSO4 and 500 mg/L Na. Cl at 0.5 MPa, 25°C, 15% recovery, and pH 6.5-7. DNF2 uses the same solutions, temperature, recovery, and pH range at 0.75 MPa.

The reported performance parameters are measured after 30 minutes of stable system operation, and stated water-yield deviation is ±15%.

Listed operating limits include a maximum pressure of 4.1 MPa, feed temperature of 5-45°C, feed pH of 3-10, cleaning pH of 2-11, maximum feed turbidity of 1.0 NTU, maximum feed SDI15 of 5, residual chlorine below 0.1, and a maximum single-element pressure drop of 15 psi.

Maximum feed flow is listed as 17 m³/h for 8040 models and 3.6 m³/h for 4040 models. Supported application fields include salt-mine recycling, halogen refining, food concentration, pharmaceutical purification, water purification, reclaimed-water reuse, cooling-water treatment, and boiler-water treatment.

Suitability remains dependent on feed composition and process objectives.

Before procurement, the buyer should confirm whether DNF1 or DNF2 provides the required ion selectivity, verify the selected 4040 or 8040 format against the intended pressure vessel and system layout, and request performance projections based on the actual feed-water analysis.

Also confirm the interpretation and unit basis of the residual-chlorine limit, required pretreatment, cleaning protocol, element quantity, customization scope, packaging, inspection criteria, warranty, and delivery terms.

DNF1 | Applications and Buyer Notes

DNF1 is organized as a sourcing-ready Filtration And Membranes reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time que

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Filtration and MembranesBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Models
DNF1-4040, DNF1-8040, DNF2-4040, DNF2-8040Based on visible page data; confirm exact value in the RFQ.
Material
Aromatic polyamideBased on visible page data; confirm exact value in the RFQ.
Structure
Spiral-woundBased on visible page data; confirm exact value in the RFQ.
Membrane type
Nanofiltration (NF)Based on visible page data; confirm exact value in the RFQ.
Standard test pH
6.5-7Based on visible page data; confirm exact value in the RFQ.
Maximum feed flow
17 m³/h for 8040;3.6 m³/h for 4040Based on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryFiltration and Membranes
Unitset
ModelsDNF1-4040, DNF1-8040, DNF2-4040, DNF2-8040
MaterialAromatic polyamide
StructureSpiral-wound
Membrane typeNanofiltration (NF)
Standard test pH6.5-7
Maximum feed flow17 m³/h for 8040;3.6 m³/h for 4040
DNF1 permeate flow40 m³/day (8040);8 m³/day (4040)
DNF2 permeate flow38 m³/day (8040);7.6 m³/day (4040)
Active membrane area37 m² for 8040;7.6 m² for 4040
Feed spacer thickness34 mil
Feed temperature range5-45°C mandated by the provided application limits.
Standard test pressure0.5 MPa for DNF1;0.75 MPa for DNF2
Standard test recovery15%
Standard test solutions2,000 mg/L MgSO4 and 500 mg/L NaCl
Standard test temperature25°C
Maximum operating pressure4.1 MPa

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

WaterTreatmentSource related sourcing paths

WaterTreatmentSource procurement phrases

WaterTreatmentSource related product samples

Supplier profile

WaterTreatmentSource Imported Supplier Pool
主营:Filtration and Membranes

View full profile >