Product specs

CategoryFiltration and Membranes
Unitset
ModelJRUF-0860
Design flux40–120 L/m²-h
Operating pH2–11
Backwash flux80–180 L/m²-h
Membrane area55 m²
NaClO tolerance5,000 ppm
CategoryFiltration And Membranes
AvailabilityInquiry required
Source date2026-07-22

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Filtration And Membranes. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

The JRUF-0860 is a column-type ultrafiltration membrane module built with reinforced hydrophilic PVDF hollow fibers. Its listed nominal pore size is 0.03 µm, with 55 m² of effective membrane area in a Φ225 × 1860 mm module. The fiber inner and outer diameters are 0.7 and 1.3 mm, respectively.

Published operating data lists a design flux of 40–120 L/m²·h, backwash flux of 80–180 L/m²·h, maximum inlet pressure of 0.4 MPa, and maximum allowable transmembrane pressure of 0.24 MPa. The stated operating range is pH 2–11 at 5–40°C, while the chemical-cleaning pH range is 1–14. Na.

ClO tolerance is listed as 5,000 ppm. Pure-water flux is specified as at least 900 L/m²·h at 0.1 MPa and 25°C. The module is listed for groundwater and surface-water purification, water treatment and reuse, and desalination pretreatment.

Reported permeate targets include SDI15 of no more than 3.0 and turbidity of no more than 0.1 NTU, subject to the feed conditions and operating protocol used for evaluation. Maximum inlet turbidity is listed as 5 NTU.

Construction details include a UPVC housing and end cap, epoxy-resin potting, a DN50 connection, and a dry weight of 30 kg. Listed operation includes cross-flow circulation, air scour, and backwashing.

Procurement confirmation: the source description contains conflicting references to inside-out and outside-in filtration, so the required flow direction and piping arrangement should be confirmed for the offered configuration.

Buyers should also confirm feed-water analysis, pretreatment requirements, recovery target, cleaning sequence, allowable oxidant exposure time, expected normalized flux, skid connection details, and the test conditions behind permeate microbiological statements.

Confirm the exact scope of supply, module quantity, inspection documents, customization details, storage procedure, preservation chemicals, shipment packaging, and warranty terms before ordering.

JRUF-0860 | Applications and Buyer Notes

JRUF-0860 is organized as a sourcing-ready Filtration And Membranes reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-tim

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Filtration and MembranesBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Model
JRUF-0860Based on visible page data; confirm exact value in the RFQ.
Design flux
40–120 L/m²-hBased on visible page data; confirm exact value in the RFQ.
Operating pH
2–11Based on visible page data; confirm exact value in the RFQ.
Backwash flux
80–180 L/m²-hBased on visible page data; confirm exact value in the RFQ.
Membrane area
55 m²Based on visible page data; confirm exact value in the RFQ.
NaClO tolerance
5,000 ppmBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryFiltration and Membranes
Unitset
ModelJRUF-0860
Design flux40–120 L/m²-h
Operating pH2–11
Backwash flux80–180 L/m²-h
Membrane area55 m²
NaClO tolerance5,000 ppm
Module dimensionsΦ225 × 1860 mm
Nominal pore size0.03 µm
Air-scour pressure0.1 MPa
Air-scour intensity90–150 L/m²-h
Chemical-cleaning pH1–14
Maximum allowable TMP0.24 MPa
Operating temperature5–40°C
Maximum inlet pressure0.4 MPa
Membrane configurationReinforced PVDF hollow fiber UF module
Fiber inner/outer diameter0.7/1.3 mm

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

WaterTreatmentSource related sourcing paths

WaterTreatmentSource procurement phrases

WaterTreatmentSource related product samples

Supplier profile

WaterTreatmentSource Imported Supplier Pool
主营:Filtration and Membranes

View full profile >